CCD status self-change to scarlet |
||
Issue descriptionCCD status changed from open to lock at no reason. > ccd State: Opened Password: none Flags: 0x000001 Capabilities: 4055414100000000 UartGscRxAPTx Y 0=Default (Always) UartGscTxAPRx Y 0=Default (Always) UartGscRxECTx Y 0=Default (Always) UartGscTxECRx Y 1=Always FlashAP Y 1=Always FlashEC Y 1=Always OverrideWP Y 1=Always RebootECAP Y 1=Always GscFullConsole Y 1=Always UnlockNoReboot Y 0=Default (Always) UnlockNoShortPP Y 0=Default (Always) OpenNoTPMWipe Y 1=Always OpenNoLongPP Y 1=Always BatteryBypassPP Y 0=Default (Always) UpdateNoTPMWipe Y 0=Default (Always) I2C Y 1=Always FlashRead Y 0=Default (Always) > ccd State: Locked Password: none Flags: 0x000001 Capabilities: 4055414100000000 UartGscRxAPTx Y 0=Default (Always) UartGscTxAPRx Y 0=Default (Always) UartGscRxECTx Y 0=Default (Always) UartGscTxECRx Y 1=Always FlashAP Y 1=Always FlashEC Y 1=Always OverrideWP Y 1=Always RebootECAP Y 1=Always GscFullConsole Y 1=Always UnlockNoReboot Y 0=Default (Always) UnlockNoShortPP Y 0=Default (Always) OpenNoTPMWipe Y 1=Always OpenNoLongPP Y 1=Always BatteryBypassPP Y 0=Default (Always) UpdateNoTPMWipe Y 0=Default (Always) I2C Y 1=Always FlashRead Y 0=Default (Always)
,
May 23 2018
This may be the incomplete unlock on the PVT devices.
,
May 23 2018
I think they should still work in the lab while locked? Mary/Randall to confirm
,
May 23 2018
Did Cr50 reboot? The state goes back to locked on reboot. If those are sequential output with no other debug output in between, not sure what happened.
,
May 23 2018
Note that the device is in testlab mode (flags&1), so 'ccd testlab open' will move the device back to the opened state.
,
May 23 2018
Re #4, The scarlet unit keep rebooting unexpected. Ref bug crbug/846012
,
May 23 2018
This is expected behavior, then. The reason is that Cr50 reboots.
,
May 24 2018
Did cr50 reboot? How are you checking that? If cr50 did reboot, then this is expected. From crbug/846012 it doesn't look like cr50 is rebooting/has rebooted in a while. Also you can't tell the cr50 reset reason unless you look at sysinfo. CCD should work ok even if ccd is locked. Cr50 is setup with all of the capabilities set to Always, so you can use them even when cr50 is locked.
,
May 24 2018
cr50 reboot during low charge. # usb_console -d 18d1:5014 > > sysinfo Reset flags: 0x00000800 (hard) Reset count: 0 Chip: g cr50 B2-D RO keyid: 0xaa66150f(prod) RW keyid: 0xde88588d(prod) DEV_ID: 0x1700a02f 0x90ecc673 Rollback: 2/2/2 > gettime Time: 0x00000003ad39d398 = 15791.149976 s |
||
►