Please check the dashboard link:
https://cros-goldeneye.corp.google.com/chromeos/healthmonitoring/testDetails?milestone=68&daysBack=30&testName=audio_AudioBasicHeadphone&board=lars
The test is keep failing on host
chromeos2-row10-rack9-host15
with error message:
===
Failure: Channel 0: Dominant frequency 0 is away from golden 1000, Channel 0: No frequency left after removing unwanted frequencies. Spectral: [(0, 0)]; After removing unwanted frequencies: [], Channel 1: Dominant frequency 0 is away from golden 2000, Channel 1: No frequency left after removing unwanted frequencies. Spectral: [(0, 0)]; After removing unwanted frequencies: []
===
and the recorded file don't have signal (in the attachment).
But the test will pass on host
chromeos2-row10-rack9-host17 and chromeos15-audiobox8-host1.
[Action]
Need to check the 4ring 3.5mm audio cable between DUT and its chameleon on the host chromeos2-row10-rack9-host15.
Thanks!
|
Deleted:
lars0514.png
7.4 KB
|