Regression: Volume & brightness sliders are seen chopped in 'Reset this chrome device' screen. |
||||||||||||||||||||||
Issue descriptionChrome Version: 59.0.3071.39/9460.27.0 beta channel Peppy,Paine,Minnie,Jerry OS: Chrome OS What steps will reproduce the problem? (1)Sign in to chrome >> Navigate to chrome://md-settings/reset page. (2)Click on power wash option and click Restart button (3)Now in 'Reset this chrome device' screen, try decreasing or increasing either brightness or volume and Observe Volume & brightness sliders Expected:Volume & brightness sliders should not be seen chopped in 'Reset this chrome device' screen. Actual: Instead,Volume & brightness sliders are seen chopped. This is regression issue as it is working fine in 55.0.2883.105/8872.76.0 stable channel peppy. Note: Issue is also seen in latest M60 #60.0.3089.0/9531.0.0 dev channel Peppy. Attaching screen shots for reference.
,
May 8 2017
This is part of the system tray UI and unrelated to settings. -> tdanderson@ to triage
,
May 8 2017
+xiyuan@, +oshima@, +jamescook@ - This looks like some weird interaction within views?
,
May 8 2017
This could be due to any number of things: * jdufault@'s recent work on the login/lock screens * minch@'s recent work on the volume (but not brightness) slider * alemate@'s new OOBE experience * The MD-ification of the system menu and slider The provided bisect range (m-55 to m-59/60) is far too large. Applying Needs-Bisect to request a revision-level bisect on the Chromium CL responsible (note that the offending CL is almost certainly in the Chromium, not Chromium OS, codebase).
,
May 8 2017
Any webui should not be interacting with system tray. oobe/login/lock are a single views::WebView covering the entire screen.
,
May 8 2017
I'll bet the "work area" for the screen is incorrect. No idea why that would happen, though. I'm also unclear whether the status area (like the network icon and clock) should appear during these flows or not.
,
May 8 2017
Re #6: I think that the status area should remain visible during these flows, as a user may wish to switch networks or enable an a11y feature.
,
May 8 2017
I tried to revert my cl about the volume slider. This bug can still repros with my CL reverted locally. https://codereview.chromium.org/2812223005/
,
May 9 2017
As we don not have bisect setup for chrome OS providing following info.Hope this is will be helpful. Good:55.0.2883.105/8872.76.0 Bad:56.0.2924.121/9000.97.0 Note: Issue is also reproducible on 57.0.2987.154/9202.71.0 Beta and 58.0.3029.98/9334.64.0 Stable. Thanks!
,
May 9 2017
I will be OOO for the next ~2 weeks or so. Marking as Available in case anyone else has cycles to dig into this a bit more.
,
May 10 2017
./tools/binary-bisect.py should work for ChromeOS.
,
Jun 14 2017
,
Jun 14 2017
Back into UI > Shell triage queue.
,
Jun 23 2017
tdanderson@ have you had a chance to look at this? /triage
,
Jun 23 2017
Based on the large bisect range provided in #9, this regressed between revision #423769 (Oct 7 2016) and #433059 (Nov 18 2016). Skimming over the git revision log of chrome/browser/chromeos/login/ within this range, it looks as though jdufault@ is in the best position to suggest next steps here; I am not familiar with any of the login/lock type screens. Based on the screenshots in #0 this could be a side effect of whenever the visuals of this screen were updated (perhaps due to a change in window bounds / positioning?) As a side note, I can't reproduce this locally: with the command line flags --login-manager --login-screen=reset the sliders are not shown as clipped. This may be somehow device-specific.
,
Nov 19
<triage> Cannot reproduce on 72.0.3593.0, please reopen if seen again. </triage> |
|||||||||||||||||||||||
►