[slippy] "Local data has been cleared" message screen and "Repair screen" are missing when converting from Normal to Dev mode. |
||||||||
Issue description
Version: 8172.12.0
OS: ChromeOS
Devices: peppy,leon
What steps will reproduce the problem?
(1) Try to switch between Normal to dev mode.
a) Press "Esc + F3 + power" to enter into Recovery screen.
b) press ("Ctrl+ d" -> Enter)to switch to Dev mode.
c) Press Ctrl +d on dev screen to start the Dev mode conversion.
What is the expected output?
User should get a screen for 30seconds about informing "Local date has been cleared" after the conversion.
What do you see instead?
device is displaying a black screen for 30 seconds and dev mode conversion starts.
Please use labels and text to provide additional information.
,
Apr 25 2016
,
Apr 26 2016
+dbehr, marcheu This sounds like it might be related to freon/frecon, any chance we did something recently that would manifest in R51 on Haswell?
,
Apr 26 2016
Repair screen is also missing. Steps: 1. Start converting from Normal to dev mode. 2. Power off the device in the middle of the conversion process. 3. Power on the device. Resutl: Repair screen is missing. Device displaying black screen and rebooting after completing the repair process.
,
Apr 26 2016
,
Apr 26 2016
It is probably the same as crbug.com/589122 Could you try it on ToT? I will be merging everything for 589122 to R51 soon as well so it should fix it.
,
Apr 29 2016
This should be fixed by fixes for crbug.com/589122 So I am marking it fixed.
,
Apr 29 2016
,
May 19 2016
Verified on build 8172.39.0 |
||||||||
►
Sign in to add a comment |
||||||||
Comment 1 by sontis@chromium.org
, Apr 25 2016